sprayod Multiple-scattering correction of spray optical thickness (τ)

Loading the calculation engine (Pyodide)…

1 Input type and files

Input file required

Drop the file here or

No file selected

Frame numbers start at 0. The stop frame is not included (200:400 = frames 200–399).

If you mix up e and 10, the error is a factor of 2.3.

Reference image I0 not necessary if you use I0 frames

Drop the file here or

No file selected

If there is no I0 file, the app takes the I0 frames from the input file (frames before injection).

Dark image optional

Drop the file here or

No file selected

Optical setup: what each input means

Extinction imaging setup with the sprayod inputs Light goes from an LED through a diffuser, through the spray, and through the collection lens to the camera. The diffuser half-angle alpha sets the spread of the illumination. The collection angle theta c is the half-angle that the lens aperture D subtends at the spray, at working distance z. Scattered light inside theta c reaches the camera, so the measured optical thickness is too low. LED Diffuser α Spray d I₀ I scattered θc D Lens (f, N) Camera z
Not to scale. Scattered light that stays inside θc reaches the camera, so the measured τ is too low. sprayod corrects this.
SymbolMeaningInput
αDiffuser half-angle: half of the full diffuser angle (20° diffuser → 10°). Spread of the illumination.Section 2, 0–30°
dDroplet diameter (Sauter mean).Section 2, 2.5–21.5 µm
τMeasured optical thickness, τ = −ln(I / I₀). I₀ = light without spray, I = light through the spray.Section 1 (raw, odmap or plvf)
θcCollection half-angle: the half-angle of the lens aperture seen from the spray. θc = atan(D / 2z) = atan(f / (2·N·z)).Section 3, 0.394–3.141°
DAperture (entrance pupil) diameter, D = f / N.From f and N
f, NFocal length and F-number of the collection lens.Section 3
zWorking distance from the spray plane to the lens. With magnification m, z = f(1+m)/m.Section 3

2 Optical conditions

The half-angle is half of the full diffuser angle (20° diffuser → 10). d is the representative diameter (Sauter mean).

Extinction efficiency Q_ext
Mie calculation settings

3 Collection angle θc

Input method
Distance input

θc = atan(f / (2·N·z)). With magnification, z = f(1+m)/m.

When you enter the values, the app calculates θc immediately. Range 0.394–3.141°

4 Run

    Example: iso-octane G2 PLVF, 4 frames (half-angle 10°, d 7 µm, f 135 mm, N 2.8, z 1230 mm).